EKEPCB2 Model 3 Single Phase 3.6/7.3 KW EV Charger PCB Controller
EKEPCB2 mode3 level 2 EPC EV Charge Controller complies with IEC61851-1 or SAEJ1772 standard and PCB installation requirement. The output of the controller adopts relay switching load, the rated voltage is 230V~, and the rated current can be adjusted between 1A and 32A.
Product Profile
Product Profile
The EKEPCB2 controller is OCPP1.6J protocol with WIFI, Ethernet net communication,
which can communicate with controller with a OCPP1.6J protocol backend,
also we can support a RS485 communication for kWH meter.
The controller addtional functions including :non-contact IC card connection module, residual current monitoring unit,
DLB management, LCD dislay, kWH Meter, Electronic lock, external emergency stop pushbutton, etc.
These function must be NOTED when ordering.
Technical Data
Technical Data
Display Content
EKEPCB2 Model 3 EV Charge Controller
| Model | EKEPCB2-C/S |
| Mode | Mode 3 charging |
| Operating Voltage | AC230V±10%,50Hz |
| Outputthe PWM Signal | Max: 32A, 1-32A adjustable |
| Basic Function | 1:RCMU DC6mA leakage monitoring 2:Overtemperature protection 3:Overvolatge&Undervoltage protection 4:Over current protection 5:voltage,current,Power for real time monitoring |
| Additional Function | 1:Swape RFID card/NFC start or stop charging function with a axuliary device of RFID module and cards 2:LCD display function with a axiliary device of LCD screen 3:Elecronic lock function with a device Electronic lock 4:DLB function with a axuliary device of CT or kWH meter 5:Emergency Stop function with a axuliary device of Pushbutom switch |
| Protocol(communication) | -OCPP1.6J Protocol,Wifi,Ethernet communication |
| -Modbus-RTU protocal and RS485 communication only for kWH meter | |
| Output Auxiliary Voltage | DC12V/100mADC5V/100mA |
| Ambient Temperature | -40℃-+50℃ |
| Humidity | <=85% |
| Colling Method | Natural cooling |
| Installation Method | PCB mounted |